JC/T 908-2013 · EN 14617 · EN 15285 · GB 6566 Class A
Technical Reference Benchmarks, Fabrication Safety & Care Manual
Consolidated laboratory reference ranges recorded in the resin-bonded engineered marble catalog test sheet (applicable to resin-marble slab series only—not inorganic terrazzo, mineral powders, or PP packaging), alongside Directive 2004/37/EC wet-cutting controls and low-alkali installation rules. Always verify lot-specific CoA/test reports per purchase order.
1. Engineered Marble Series Reference Test Matrix (JC/T 908 & EN 14617 Alignment)
| Property | Standard Method | Unit | Series Reference Range (Verify per Batch) |
|---|---|---|---|
| Water Absorption | JC/T 908-2013 / EN 14617-1 | % | water absorption of 0.01%–0.02% (series reference) |
| Flexural Strength | JC/T 908-2013 / EN 14617-2 | MPa | 30.4 – 35.6 MPa |
| Compressive Strength | JC/T 908-2013 / EN 14617-15 | MPa | 110 – 139 MPa |
| Mohs Surface Hardness | EN 101 / Catalog Lab | Mohs | 3 – 4 |
| Specular Gloss (Polished) | JC/T 908-2013 | GU | 80.7 – 85.0 GU |
| Thermal Expansion | EN 14617-11 | 10⁻⁵ °C⁻¹ | 2.0 – 2.2 |
| Radioactivity Class | GB 6566-2010 | IRa / Ir | Class A (IRa < 0.1, Ir < 0.1) |
2. Mandatory Fabrication, Adhesive & Chemical Care Boundaries
- 9D Surface-Printed Slabs (Non-Full-Body): 9D veining is surface-printed rather than through-body; use 45° mitered waterfall edges and indoor UV-shielded locations only.
- Prohibit Ordinary Cement Mortar: Bond resin-marble slabs with two-component low-alkali reactive resin or C2S1 rapid-setting white adhesive over dry screeds.
- Wet Cutting (2004/37/EC) & pH-Neutral Cleaning: Execute all sawing/polishing wet with LEV dust extraction; clean calcite stone exclusively with pH 7–8 neutral detergents.